product |
Oxygen Generator |
Trademark |
Skid Mounted |
model |
LPO-30 |
Purity |
99%-99.999% |
Noise Level |
Low |
voltage |
220V |
certification |
ISO, CE, ISO1400/18001 |
manufacturer |
china |
Application |
Industry / Agriculture / Livestock / Food / Medical / Electronic |
trade mark |
LDH |
Transport Package |
Pre-Packing |
Production Capacity |
3L/H to 30L/H |
The working principle of oxygen machine
The working principle of the oxygen generator The pressure swing adsorption oxygen generator is a gas separation device that uses zeolite molecular sieve as an adsorbent, and uses the difference in the adsorption amount of oxygen and nitrogen on the surface of the molecular sieve in the compressed air to directly produce product oxygen from the compressed air through the principle of pressurized adsorption and decompression desorption.
The core configuration of the system is selected from internationally renowned brands or original imported products, with excellent quality assurance.
The system realizes automatic operation, automatic start and stop, remote start and stop, unqualified oxygen automatic emptying, and linkage control of equipment in the whole system.
Multi-function monitoring system, LCD screen, can be set including flow, purity, pressure and other related system parameters, to achieve oxygen flow, purity, pressure and other online full screen
The system directly produces oxygen from the air and consumes only electrical energy.
Remote wireless monitoring system can be selected. Real-time and dynamic monitoring of the equipment is realized, and automatic control and efficient operation of the equipment are realized.
The equipment can be maintained remotely and locally. The running state and data of the equipment can be monitored remotely and in real time. The equipment can be remotely debugged and upgraded.
LPO series
Working environment parameters
Working environment temperature : 5-45 °C
Adapt to altitude : below 4000 meters. ( Consult company engineers in high altitude areas )
Compressed air inlet parameters
Compressed air quality : meet ISO8573-1 class 1-4-1
Air inlet pressure : 7.5bar ( g )
ltem |
model |
Capacity(Nm3/h) |
size(mm) |
Weight(KG) |
Power(Kw) |
Air Inlet |
Oxygen outlet |
1 |
LPO-5 |
1-5 |
770*750*1800 |
380 |
0.2 |
DN15(G1/2") |
DN15(G1/2") |
2 |
LPO-10 |
6-10 |
770*750*2200 |
450 |
0.2 |
DN15(G1/2") |
DN15(G1/2") |
3 |
LPO-15 |
10-15 |
880*780*2400 |
780 |
0.2 |
DN20(3/4") |
DN15(G1/2") |
4 |
LPO-20 |
16-20 |
1550*1000*2500 |
1260 |
0.2 |
DN25(G1") |
DN20(3/4") |
5 |
LPO-25 |
21-25 |
1550*1000*2600 |
1480 |
0.2 |
DN40(G11/2") |
DN25(G1") |
6 |
LPO-30 |
26-30 |
1550*1000*2800 |
1680 |
0.2 |
DN40(G11/2") |
DN25(G1") |
7 |
LPO-50 |
50-55 |
1750*1200*3150 |
2150 |
0.2 |
DN40(G11/2") |
DN25(G1") |
Typical applications for oxygen generator
Aquaculture
Torch
Fish tank
Welding
Hospital
Main equipment for oxygen generator
Air compressor
Refrigeration dryer
Air buffer
Oxygen generator
Oxygen buffer
Oxygen generator Feature
1.Unique CMS safeguard are used to lengthen the life of CMS;
2.Nitrogen chain liberated air automatic system is used to guarantee the quality of nitrogen;
3.Air Cylinder Pressure are used to avoid CMS chalking by the high speed air impact;
4.Reasonable structural design are make sure the transport, lifting and installation easier;
5.Easy to use, plug and play.
Oxygen generator of production equipment
Bevelling machine
Bending roll
Automatic welding machine
Automatic casing cutter
Automatic arc-submerging welder
Oxygen generator Performance guarantee and after-sale service
All equipment in the contract be designed and manufactured in accordance with current Chinese & professional standard and regulations;
Warranty period: 12 months after formal running or 18 months after delivery, whichever occurs first;
Afterwards, prompt maintenance service and spare parts will be available with charge.
Documents and drawings provided by the seller shall be drawn in English version.
Oxygen generator QA
1. What is the difference between a VPSA oxygen generator and a PSA oxygen generator?
The PSA oxygen generator is suitable for use under 300 cubic meters and has the characteristics of simple and convenient, movable.
VPSA oxygen generator is suitable for more than 300 cubic meters of use, the greater the gas volume, the lower the energy consumption.
2. What is the difference between a fish pond aerator and a fish pond oxygen generator?
The aerator is a self-contained air pump that mixes 20% of the oxygen in the air into the water.
The oxygen generator is dissolved in water by producing 90% pure oxygen.
Merchants need to consider the choice of aerobics or oxygen generators based on the type of fry, increasing the oxygen production rate to increase the production cycle, and the total ratio of fish ponds.
3. What is the purity of the PSA oxygen generator?
The purity of the general PSA oxygen generator is 90%-93%.
Our company's PSA oxygen generator can reach 95%, 98%, up to 99+%.
4. What should I pay attention to when using the oxygen generator for ozone?
Ozone supporting oxygen generators mainly need to select an oxygen generator with stable gas volume and purity to avoid ozone concentration and production due to instability.
5. How to maintain the PSA oxygen generator
The daily maintenance of the oxygen generator is relatively simple:
(1) The air compressor should be regularly maintained, air filter, oil, and oil should be replaced by the manufacturer at regular intervals according to the instructions.
(2) The dryer should regularly check the pressure of the refrigerant to make it timely. The heat sink should be cleaned with compressed air every day. The filter element should be replaced regularly. The normal temperature is 8000H. It depends on the specific situation and pressure difference.
(3) Open the air storage tank drain once a day and drain the condensate from the air.
(4) Check the automatic drainer daily to avoid clogging and lose drainage. If it is blocked, open the manual valve slightly, close the self-discharge valve and then remove the automatic drainer to disassemble and clean. When cleaning the automatic drain, use soap to clean.
(5) The oxygen generator mainly checks the working pressure of the adsorption tower, and records the purity and flow rate.