Medical Oxygen Generator Purity 99.5%

Product Details
Customization: Available
Application Fields: Medical, Medical
Certification: RoHS, ISO, CE
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW
  Support payments in USD
Secure payments: Every payment you make on Made-in-China.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Manufacturer/Factory, Trading Company

360° Virtual Tour

Secured Trading Service
Diamond Member Since 2021

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

  • Medical Oxygen Generator Purity 99.5%
  • Medical Oxygen Generator Purity 99.5%
  • Medical Oxygen Generator Purity 99.5%
  • Medical Oxygen Generator Purity 99.5%
  • Medical Oxygen Generator Purity 99.5%
  • Medical Oxygen Generator Purity 99.5%
Find Similar Products
  • Overview
  • IndustirlUsage
Overview

Basic Info.

Model NO.
LPO-50
Condition
New
Noise Level
Low
Parts
Adsorption Tower
Purpose
Gas Separation
Voltage
380V
Warranty
1year
Type
Psa
Purity
90-99.5%
Usage
Oxygen
Machine Size
Medium
Transport Package
Wooden Case
Specification
as required
Trademark
LDHGAS
Origin
China
HS Code
8414804090
Production Capacity
5000 Units/Year

Packaging & Delivery

Package Size
250.00cm * 150.00cm * 220.00cm
Package Gross Weight
2000.000kg

Product Description

IndustirlUsage

 


PSA Oxygen Generator principle

PSA oxygen generator is based on the pressure swing adsorption principle, the use of high-quality zeolite molecular sieve as adsorbent, under a certain pressure, from the air to make oxygen. After purification and drying compressed air, pressure adsorption and decompression desorption are carried out in the adsorber. Due to the aerodynamic effect, the diffusion rate of nitrogen in the pores of zeolite molecular sieve is much higher than that of oxygen. Nitrogen is preferentially adsorbed by zeolite molecular sieve, and oxygen is enriched in the gas phase to form finished oxygen. After decompression to atmospheric pressure, adsorbent desorbed nitrogen and other impurities, to achieve regeneration. In general, two adsorption towers are set up in the system, one tower adsorption oxygen production, the other tower desorption regeneration, through the PLC program controller control pneumatic valve opening and closing, so that the two towers alternate circulation, in order to achieve the purpose of continuous production of high-quality oxygen.





 

7.LDH Oxygen production machine technical characteristics

Energy saving-Reliable-stable quality
Similar products, smaller in volume, save space
Using high-performance molecular sieve combined with our unique L-Tech technology to reduce gas consumption and more energy saving
 
automatic start-stop
Pressure start-stop remote start-stop and remote diagnosis
Intelligent Internet of Things
Flow purity pressure touchscreen display



















 
  • The multi-functional monitoring system realizes the online full-screen display of gas flow, purity and pressure. For the parameters that need to be observed (such as purity, flow and pressure), the real-time curve tool of the upper computer so ftware is used to configure the curve attributes, and the parameter curve can be displayed in real time during operation.
  • Historical trend curve:
Curve browsing function for design history data.At runtime, you can draw a trend rendering of the corresponding historical data according to the needs, which is used to view the data and status trends to summarize the rules.as illustrated in following figure


Medical Oxygen Generator Purity 99.5%Medical Oxygen Generator Purity 99.5%

 

8.Flow chart of the LDH Oxygen production system

9.Design environmental parameters

Ambient temperature: 5~30ºC
Humidity of 70% Excessive humidity leads to low gas volume
Air dust content is 20mg / m3
in the air H2S,SO2The content was 5ppm
in the air CO2The content was 350ppm
in the air C2H2Content was 0.5ppm
The CnHm content in the air was 20ppm
Air no irritating odor and corrosive gas, well ventilated, circulation,
Equipment site, installed in the room, flat ground, load-bearing, reserved drainage ditch.
Public Works Conditions
with power distribution cabinet, power supply to the equipment power connection point.
 

10. After sale service

Provide customers with technical consultation and operation training; b: preset some spare parts in a planned way to meet customer needs, and take emergency measures to meet the spare parts urgently needed by customers; c: provide commissioning service; d: provide visiting service (at least once a year e: collect customer demand information, accept customer quality objections, and take timely corrective and preventive measures;
  • After-sales engineer introduction;
The company service engineer after professional skills training, strict professional skills assessment, with first-class technology, service level for the users of comprehensive service.
  • Emergency maintenance schedule;
A: Give the user a clear reply within 2 hours after receiving the information of the user's equipment failure;
In b: arrive at the user site within 48 hours to ensure the normal use of users.
  • Price and supply channels of main spare parts;
Commonused accessories perennial inventory, the price is lower than the market average level.
  • Featured services;
A: Establish electronic user files and assist users in equipment management;
B: Regularly remind users to replace vulnerable parts, check equipment and matters needing attention;
C: Regular product use tracking service and after-sales service consultation;
D: Set up after-sales service column records.
  • training plan.
Train the operators to operate the equipment skillfully;
Let the maintenance personnel master the daily maintenance and maintenance work of the equipment; when the service personnel visit the users, conduct secondary training to the operators, and the operation and maintenance personnel can further understand the equipment.