PSA Oxygen Generator: Cutting-Edge Onsite Gas Separation Technology
The Pressure Swing Adsorption (PSA) Oxygen Generator represents the pinnacle of advanced gas separation technology, offering a reliable and efficient solution for onsite oxygen production. Leveraging the power of high-quality zeolite molecular sieves as the adsorbent, our PSA systems separate oxygen from compressed air to deliver purity levels up to 95%, effectively replacing traditional bottled oxygen supply.
Key Features & Advantages:
Adaptive Purity Control: The product purity can be modulated according to changes in flow demand, providing flexibility for various industrial and medical applications.
Safety & Energy Efficiency: Operating at medium to low pressures, the PSA technology ensures a safe working environment while minimizing energy consumption.
Ease of Operation & Maintenance: Equipped with touchscreen control panels, these units offer fully automated operation, requiring minimal supervision and facilitating easy maintenance procedures.
Customizable Solutions: Tailored for different sectors such as chemical, petroleum, food industries, and more, the 10 cubic meter PSA Oxygen Generator weighs 950kg and boasts a processing capacity of up to 100 cubic meters per hour, delivering oxygen with a purity not less than 93% and an oxygen dew point below -40°C.
Working Principle: The PSA process involves the selective adsorption of nitrogen from compressed air onto the surface of the molecular sieve, leaving behind a concentrated stream of oxygen. The adsorption and desorption cycles occur alternately under controlled pressure swings to ensure continuous and consistent oxygen output.
Applications Overview: From critical emergency medical oxygen supplies to supporting large-scale industrial processes that require a steady flow of pure oxygen, PSA Oxygen Generators are designed to meet diverse needs. They play a pivotal role in alleviating hypoxia symptoms in patients, serving as a cornerstone in clinical treatments for pathologically-induced oxygen deficiencies, and contributing to environmental sustainability through their energy-efficient and cost-effective design.
Technical Specifications: Powered by either 380V/220V, 50/60Hz electrical supply, our PSA units operate with a noise level not exceeding 75dB(A) and boast a stable output pressure of ≥0.3Mpa. With twin vessels filled with specialized ZMS, they ensure continuous and efficient oxygen generation without compromising on performance or reliability.
Innovation and Comparison: Compared to VPSA (Vacuum Pressure Swing Adsorption) systems, PSA technology is particularly well-suited for smaller to medium-sized oxygen production requirements, offering a robust balance between capital investment, operating costs, and overall efficiency.
Invest in PSA Oxygen Generators for a sustainable and dependable oxygen supply solution that delivers optimal performance and unparalleled value across multiple industries.
Product Parameters
|
Model |
purity |
Size |
Weight |
Inlet |
Oulet |
1 |
LPO-3 |
90-95% |
1200*900*1900 |
520 |
DN15 |
G1/2" |
2 |
LPO-5 |
90-95% |
1350*1050*2100 |
750 |
DN20 |
G1/2" |
3 |
LPO-10 |
90-95% |
1550*1300*2100 |
1100 |
DN25 |
G1/2" |
4 |
LPO-15 |
90-95% |
1700*1450*2350 |
1500 |
DN32 |
G1/2" |
5 |
LPO-20 |
90-95% |
1800*1550*2350 |
1750 |
DN32 |
G1/2" |
6 |
LPO-25 |
90-95% |
1900*1650*2400 |
2000 |
DN40 |
G1" |
7 |
LPO-30 |
90-95% |
2000*1750*2400 |
2250 |
DN40 |
G1/2" |
8 |
LPO-35 |
90-95% |
1970*1250*2800 |
1800 |
DN40 |
DN25 |
9 |
LPO-40 |
90-95% |
2000*1300*2460 |
2380 |
DN40 |
DN25 |
10 |
LPO-50 |
90-95% |
2000*1300*2800 |
2790 |
DN50 |
DN25 |
11 |
LPO-60 |
90-95% |
2000*1300*2800 |
2930 |
DN50 |
DN25 |
12 |
LPO-70 |
90-95% |
2200*1500*2900 |
3190 |
DN50 |
DN40 |
13 |
LPO-80 |
90-95% |
2200*1500*2900 |
3585 |
DN50 |
DN40 |
14 |
LPO-90 |
90-95% |
2250*1550*2980 |
3940 |
DN50 |
DN40 |



Oxygen generator Feature
1.Unique CMS safeguard are used to lengthen the life of CMS;
2.Nitrogen chain liberated air automatic system is used to guarantee the quality of nitrogen;
3.Air Cylinder Pressure are used to avoid CMS chalking by the high speed air impact;
4.Reasonable structural design are make sure the transport, lifting and installation easier;
5.Easy to use, plug and play.
After Sales Service
LDH is dedicated to providing exceptional customer support throughout the entire product lifecycle. Our after-sales service includes:
Comprehensive Warranty: We offer a full warranty covering parts and labor during the warranty period, ensuring peace of mind.
Equipment Archiving: We establish comprehensive electronic and paper records for each installed unit, ensuring efficient tracking and management.
Rapid Response: In the event of equipment failure, we guarantee a swift response, with our technicians within 24 hours to resolve issues.
Training and Education: We offer comprehensive operator training and proficiency assessments to ensure customers can use the equipment effectively and safely.
FAQ
1. What is the difference between a VPSA oxygen generator and a PSA oxygen generator?
The PSA oxygen generator is suitable for use under 300 cubic meters and has the characteristics of simple and convenient, movable.
VPSA oxygen generator is suitable for more than 300 cubic meters of use, the greater the gas volume, the lower the energy consumption.
2. What is the difference between a fish pond aerator and a fish pond oxygen generator?
The aerator is a self-contained air pump that mixes 20% of the oxygen in the air into the water.
The oxygen generator is dissolved in water by producing 90% pure oxygen.
Merchants need to consider the choice of aerobics or oxygen generators based on the type of fry, increasing the oxygen production rate to increase the production cycle, and the total ratio of fish ponds.
3. What is the purity of the PSA oxygen generator?
The purity of the general PSA oxygen generator is 90%-93%.
Our company's PSA oxygen generator can reach 95%, 98%, up to 99+%.
4. What should I pay attention to when using the oxygen generator for ozone?
Ozone supporting oxygen generators mainly need to select an oxygen generator with stable gas volume and purity to avoid ozone concentration and production due to instability.
5. How to maintain the PSA oxygen generator?
The daily maintenance of the oxygen generator is relatively simple:
(1) The air compressor should be regularly maintained, air filter, oil, and oil should be replaced by the manufacturer at regular intervals according to the instructions.
(2) The dryer should regularly check the pressure of the refrigerant to make it timely. The heat sink should be cleaned with compressed air every day. The filter element should be replaced regularly. The normal temperature is 8000H. It depends on the specific situation and pressure difference.
(3) Open the air storage tank drain once a day and drain the condensate from the air.
(4) Check the automatic drainer daily to avoid clogging and lose drainage. If it is blocked, open the manual valve slightly, close the self-discharge valve and then remove the automatic drainer to disassemble and clean. When cleaning the automatic drain, use soap to clean.
(5) The oxygen generator mainly checks the working pressure of the adsorption tower, and records the purity and flow rate.